Barksdale Series 423, 425, 426 - General Industrial Transducer (Amplified)
Barksdale
Ürün Kodu: Series 423, 425, 426
Marka: Barksdale
Teklif Al! info@fabrikaparca.com
Barksdale Series 423, 425, 426 - General Industrial Transducer (Amplified) için Açıklama:
Barksdale's Series 423 and 426 Transducers and 425 Transmitters are general purpose, industrial grade transducers, ideal for use in general industrial applications when a robust transducer is required. Wetted parts are constructed of 17-4PH and 300 Series Stainless Steel, with NEMA 4 enclosures constructed of 304 Stainless Steel. These units feature a stable, diffused silicon sensor that achieves .25% accuracy, have pressure ranges from 0-10,000 psi and are available in 5V, 10V or 4-20 mA outputs. High pressure snubbers are standard on units at 2,000 psi and above. Optional surge voltage protection to 6kV is available. A variety of process fittings and electrical connections are available to meet your needs.
General Specifications*
Accuracy (LH & R): | ±0.25% FSO (±0.5% for vacuum only [-23]) at 75°F (24°C), typical |
Long Term Stability: | ±0.5% FSO of calibration curve |
Typical Life Cycle: | 100 million cycles |
Proof Pressure: | 2 times rated pressure or 13,000 psi max. (884 bar), whichever is less |
Input: 423: 426: 425: | Excitation voltage: 11 to 30 VDC Excitation voltage: 14 to 30 VDC Excitation voltage: 12 to 30 VDC |
Supply Current: | 16 mA maximum (no load) |
Min. Load Resistance: | 2K ohms (voltage series only) |
Output: 423: 426: 425: | Output: 0.5 to 5.5 VDC Full scale output: 5.0 VDC ± 1% Zero output: 0.5 VDC ± 2% Output: 1 to 11 VDC Full scale output: 10 VDC ± 1% Zero output: 1.0 VDC ± 2% Output: 4 to 20 mA Full scale output: 16 mA ± 1% Zero output: 4 mA ± 2% Span: 16mA |
Wetted Parts: | 17-4 PH (fitting) & 300 stainless steel (sensor) |
Enclosure: | NEMA 4, 300 series stainless steel |
Pressure Connection: | 1/4"-18 NPT male (STD) |
Response Time: | 2 kHz |
Electrical Connection: | 3 conductor for voltage series and 2 conductor for current series, 24 awg, PVC jacketed, shielded cable, 3 ft. (1 m) long with integral strain relief and case ground. |
Temperature Ranges: Operating: Compensated: Storage: | -40° to 185°F (-40° to 85°C ) 30° to 160°F (-1° to 71°C) -40° to 185°F (-40° to 85°C) |
Temperature Shift: Zero & Span: | ± 0.0125% per °F over compensated range, 75°F reference |
Vibration: | 15 g´s, 10-2000 Hz, MIL-STD 202 |
Shock: | 50 g´s, 11 ms, MIL-STD 202 Method 213, Cond. G. |
Built-in Protection: | Conducted & radiated RF emissions/ interference to EN 55011 IEC 801-2, -3, -4, -5, and -6 EN/IEC 6100-4-2, -3, -4, -5, -6 Refer to engineering drawing for details. |
Weight: 423 & 426: 425: | 7.4 oz. (221 grams) to 1000 psi 9.9 oz. (281 grams) 2,000 psi and higher 7.4 oz. (210 grams) to 1000 psi 9.4 oz. (266 grams) 2,000 psi and higher |
Warranty: | 1 year warranty |
* See product confi gurator for additional options. |
Wiring Code
Voltage - Series 423, 426 | |||
---|---|---|---|
T2 | H3 | ||
A | 1 | Red | + Excitation |
B | 3 | White | + Output |
C | 2 | Black | Common |
D | 4 | Bare | Case Drain |
Milliamp - Series 425 | |||
A | 1 | Red | + Excitation |
B | 2 | Black | - Excitation |
D | 4 | Bare | Case Drain |
Barksdale Series 423, 425, 426 - General Industrial Transducer (Amplified) için önerilen ürünler: