Barksdale Series 423X, 425X, 426X - Series 423 X, 425 X, 426 X Explosion Proof Transducer (Amplified)
Barksdale
Ürün Kodu: Series 423X, 425X, 426X
Marka: Barksdale
Teklif Al! info@fabrikaparca.com
Barksdale Series 423X, 425X, 426X - Series 423 X, 425 X, 426 X Explosion Proof Transducer (Amplified) için Açıklama:
Barksdale's 420X Series Explosion Proof Transducers prevent an explosion from occurring when operated in a Division 1 environment. Barksdale's 420X Series transducers prevent personal injury and machinery damage by preventing the explosion the first place. Energy generated within the transducer is of such a low level that intermittently present flammable vapors will not be ignited. External zener barriers are not required in order to meet UL requirements for a non-incendive installation. The lower cost of not having to install zener barriers means that the positive aspects of intrinsically safe and explosion proof are combined in Barksdale non-incendive transducers. Three models are available: Series 423X (0-5V), Series 425X (4-20mA) and Series 426X (0-10V).
General Specifications*
Accuracy (LH & R): | ±0.25% FSO at 75°F (±0.5% for vacuum only [-23]) typical |
Long Term Stability: | ±0.5% FSO of calibration curve |
Typical Life Cycle: | 100 million cycles |
Proof Pressure: | 2 times rated pressure or 13,000 psi max. (884 bar), whichever is less |
Input: 423X: 426X: 425X: | Excitation voltage: 11 to 30 VDC Excitation voltage: 14 to 30 VDC Excitation voltage: 12 to 28 VDC |
Supply Current: | 3.0 mA maximum (no load) |
Output: 423X: 426X: 425X: | Output: 0.5 to 5.5 VDC Full scale output: 5.0 VDC ± 1% Zero output: 0.5 VDC ± 2% Output: 1 to 11 VDC Full scale output: 10 VDC ± 1% Zero output: 1.0 VDC ± 2% Output: 4 to 20 mA Full scale output: 16 mA ± 1% Zero output: 4 mA ± 2% |
Wetted Parts: | 17-4 PH (fitting)** & 300 series stainless steel (sensor) |
Enclosure: | NEMA 4X, 300 series stainless steel |
Pressure Connection: | 1/4”-18 NPT male |
Electrical Connection: | 3 conductor for voltage series and 2 conductor for current series, 24 awg, PVC jacketed, shielded cable, 3 ft. (1 m) long with integral strain relief and case ground (standard). |
Temperature Ranges: Operating: Compensated: Storage: | -40° to 185°F (-40° to 85°C) 0° to 160°F (-18° to 71°C) -40° to 185°F (-40° to 85°C) |
Temperature Shift: Zero & Span: | 0.0125% per °F over compensated range reference |
Vibration: | 15 g’s, 10-2000 Hz, MIL-STD 202 |
Shock: | 50 g’s, 11 mS, MIL-STD 202 Method 213, Cond. G. |
Approvals: All: 425X only: | cULus approved as telemetering equipment for use in hazardous locations (UL File E146589, WYMV, WYMV7) as follows: Class I, Div. 1, Groups A, B, C & D Class II, Groups E, F & G. ATEX/IECEx Certification: CE 0081 Ex II 2 G D, Ex d IIC 91°C (T5) Gb, Ex tb IIIC T100°C Db IP66, -40°C ? Tamb ? 85°C, DEMKO 04 ATEX 0334369, IECEx UL 13.0036X |
Weight: 423X & 426X: 425X: | 7.4 oz. (221 grams) to 1000 psi 9.9 oz. (281 grams) 2,000 psi and higher 7.4 oz. (210 grams) to 1000 psi 9.4 oz. (266 grams) 2,000 psi and higher |
Warranty: | 1 year warranty |
* See product confi gurator for additional options. ** Consult factory for 316SS option. |
Wiring Code
MILLIVOLT SERIES - 423X & 426X | |
---|---|
Cable | Signal |
Red | + Excitation |
White | + Output |
Black | Common |
Bare | Drain |
MILLIAMP SERIES - 425X | |
Red | + Excitation |
Black | - Excitation |
Bare | Drain |
Barksdale Series 423X, 425X, 426X - Series 423 X, 425 X, 426 X Explosion Proof Transducer (Amplified) için önerilen ürünler: