Marka | Barksdale |
---|---|
Ürün | Non-Incendive Transducer |
Ürün Kodu | Series 433, 435, 436 |
Artikel | - |
Ülke | United States (US) |
Durumu | Yeni / Kullanılmamış |
Barksdale's 430 Series Non-IncendiveTransducers prevent an explosion from occurring when operated in a Division II environment. Barksdale's 430 Series, non-incendive transducers prevent personal injury and machinery damage by preventing the explosion in the first place. Energy generated within the transducer is of such a low level that intermittently present flammable vapors will not be ignited. External zener barriers are not required in order to meet UL requirements for a non-incendive installation. Three models are available: Series 433 (0-5V), Series 435 (4-20mA) and Series 436 (0-10V).
Accuracy (LH & R): | ±0.25% FSO at 75°F (±0.5% for vacuum only [-23]) typical |
Long Term Stability: | ±0.5% FSO of calibration curve |
Typical Life Cycle: | 100 million cycles |
Proof Pressure: | 2 times rated pressure or 13,000 psi max. (884 bar), whichever is less |
Input: 433: 436: 435: | Excitation voltage: 11 to 30 VDC Excitation voltage: 14 to 30 VDC Excitation voltage: 12 to 28 VDC |
Supply Current: | 3.0 mA maximum (no load) |
Min. Load Resistance: | 2K ohms (voltage series) |
Output: 433: 436: 435: | Output: 0.5 to 5.5 VDC Full scale output: 5.0 VDC ± 0.8% Zero output: 0.5 VDC ± 0.4% Output: 1 to 11 VDC Full scale output: 10 VDC ± 0.4% Zero output: 1.0 VDC ± 0.2% Output: 4 to 20 mA Full scale output: 16 mA ± 1% Zero output: 4 mA ± 2% |
Wetted Parts: | 17-4 PH (fitting) & 300 stainless steel (sensor) |
Enclosure: | NEMA 4, 300 series stainless steel |
Pressure Connection: | 1/4”-18 NPT male |
Response Time: | 2kHz |
Electrical Connection: | 3 conductor for voltage series and 2 conductor for current series, 24 awg, PVC jacketed, shielded cable, 3 ft. (1 m) long with integral strain relief and case ground (standard). |
Temperature Ranges: Operating: Compensated: Storage: | -40° to 158°F (-40° to 70°C) -40° to 158°F (-40° to 70°C) -40° to 185°F (-40° to 85°C) |
Temperature Shift: Zero & Span: | 0.01% per °F over compensated range |
Vibration: | 15 g’s, 10-2000 Hz, MIL-STD 202 |
Shock: | 50 g’s, 11 ms, MIL-STD 202 Method 213, Cond. G. |
Approvals: | Nonincendive pressure transmitters are UL and cUL approved as telemetering equipment for use in Div. 2 hazardous locations as follows: Class I, Div. 2, Groups A, B, C & D Class II, Div. 2 Groups F & G Agency approval varies by electrical termination type as follows: H5(-E) models are cULus listed in UL File E146589, (WYMV, WYMV7). H3(-E), T4(-E) & T5 (-E) models are cURus recognized components in UL File E146589, (WYMV2, WYMV8). |
Weight: 433 & 436: 435: | 7.4 oz. (221 grams) to 1,000 psi 9.9 oz. (281 grams) 2,000 psi and higher 7.4 oz. (210 grams) to 1,000 psi 9.4 oz. (266 grams) 2,000 psi and higher |
Warranty: | 1 year warranty |
* See product confi gurator for additional options. |
MILLIVOLT SERIES - 433 & 436 | ||
---|---|---|
(T4/T5) | (H3/H5) | Signal |
1 | Red | + Excitation |
3 | White | + Output |
2 | Black | Common |
4 | Bare | Drain |
MILLIAMP SERIES - 435 | ||
1 | Red | + Excitation |
2 | Black | - Excitation |
4 | Bare | Case Drain |
İmtek Mühendislik Ltd .Şti. Yurtiçi ve Yurtdışında ihtiyaç duyulan teknolojik malzemeleri elektronik,hidrolik, pnömatik sistem yedek parçalarını en hızlı şekilde tedarik etmek amacıyla 2001 yılında Adana'da kurulmuştur.
Türkiye' nin Her Yerinden44448 19Telif Hakkı © İmtek Mühendislik Ltd. Şti. Tüm hakkı saklıdır.