Barksdale Series 433, 435, 436 - Non Incendive Transducer
Barksdale
Ürün Kodu: Series 433, 435, 436
Marka: Barksdale
Teklif Al! info@fabrikaparca.com
Barksdale Series 433, 435, 436 - Non Incendive Transducer için Açıklama:
Barksdale's 430 Series Non-IncendiveTransducers prevent an explosion from occurring when operated in a Division II environment. Barksdale's 430 Series, non-incendive transducers prevent personal injury and machinery damage by preventing the explosion in the first place. Energy generated within the transducer is of such a low level that intermittently present flammable vapors will not be ignited. External zener barriers are not required in order to meet UL requirements for a non-incendive installation. Three models are available: Series 433 (0-5V), Series 435 (4-20mA) and Series 436 (0-10V).
General Specifications*
Accuracy (LH & R): | ±0.25% FSO at 75°F (±0.5% for vacuum only [-23]) typical |
Long Term Stability: | ±0.5% FSO of calibration curve |
Typical Life Cycle: | 100 million cycles |
Proof Pressure: | 2 times rated pressure or 13,000 psi max. (884 bar), whichever is less |
Input: 433: 436: 435: | Excitation voltage: 11 to 30 VDC Excitation voltage: 14 to 30 VDC Excitation voltage: 12 to 28 VDC |
Supply Current: | 3.0 mA maximum (no load) |
Min. Load Resistance: | 2K ohms (voltage series) |
Output: 433: 436: 435: | Output: 0.5 to 5.5 VDC Full scale output: 5.0 VDC ± 0.8% Zero output: 0.5 VDC ± 0.4% Output: 1 to 11 VDC Full scale output: 10 VDC ± 0.4% Zero output: 1.0 VDC ± 0.2% Output: 4 to 20 mA Full scale output: 16 mA ± 1% Zero output: 4 mA ± 2% |
Wetted Parts: | 17-4 PH (fitting) & 300 stainless steel (sensor) |
Enclosure: | NEMA 4, 300 series stainless steel |
Pressure Connection: | 1/4”-18 NPT male |
Response Time: | 2kHz |
Electrical Connection: | 3 conductor for voltage series and 2 conductor for current series, 24 awg, PVC jacketed, shielded cable, 3 ft. (1 m) long with integral strain relief and case ground (standard). |
Temperature Ranges: Operating: Compensated: Storage: | -40° to 158°F (-40° to 70°C) -40° to 158°F (-40° to 70°C) -40° to 185°F (-40° to 85°C) |
Temperature Shift: Zero & Span: | 0.01% per °F over compensated range |
Vibration: | 15 g’s, 10-2000 Hz, MIL-STD 202 |
Shock: | 50 g’s, 11 ms, MIL-STD 202 Method 213, Cond. G. |
Approvals: | Nonincendive pressure transmitters are UL and cUL approved as telemetering equipment for use in Div. 2 hazardous locations as follows: Class I, Div. 2, Groups A, B, C & D Class II, Div. 2 Groups F & G Agency approval varies by electrical termination type as follows: H5(-E) models are cULus listed in UL File E146589, (WYMV, WYMV7). H3(-E), T4(-E) & T5 (-E) models are cURus recognized components in UL File E146589, (WYMV2, WYMV8). |
Weight: 433 & 436: 435: | 7.4 oz. (221 grams) to 1,000 psi 9.9 oz. (281 grams) 2,000 psi and higher 7.4 oz. (210 grams) to 1,000 psi 9.4 oz. (266 grams) 2,000 psi and higher |
Warranty: | 1 year warranty |
* See product confi gurator for additional options. |
Wiring Code
MILLIVOLT SERIES - 433 & 436 | ||
---|---|---|
(T4/T5) | (H3/H5) | Signal |
1 | Red | + Excitation |
3 | White | + Output |
2 | Black | Common |
4 | Bare | Drain |
MILLIAMP SERIES - 435 | ||
1 | Red | + Excitation |
2 | Black | - Excitation |
4 | Bare | Case Drain |
Barksdale Series 433, 435, 436 - Non Incendive Transducer için önerilen ürünler: