Standards
Class 1 or 2 Group X according to IEC 61672-1:2013
Approval according to IEC 61672-1:2002 (I.N.RI.M. Approval Certificate No. 07-0124-02)
Class 1 or 2 according to IEC 60651:2001 and IEC 60804:2000
Class 1 according to IEC 61260:1995 and IEC 61260-1:2014
Type 1 or 2 according to ANSI S1.4-1983 and S1.43-1997
Class 1-D, order 3, Extended range according to ANSI S1.11-1986
½ inch Microphone UC52 condenser type, pre-polarized, for free field
Dynamic Range 30 dBA ÷ 143 dB Peak
Linearity range 80 dB
Acoustic Parameters Spl, Leq, LeqI, SEL, LEP,d, Lmax, Lmin, Lpk, Dose, Ln
Frequency Weightings Simultaneous A, C, Z (only C and Z for Lpk)
Time Weighting Simultaneous FAST, SLOW, IMPULSE
Integration From 1s to 99 hours with Back-Erase function
Spectrum Analysis
Parallel CPB filters in real time complying with class 1 specifications according to IEC 61260
• Octave bands from 32 Hz to 8 kHz
• Third octave bands from 25 Hz to 12.5 kHz (“Third Octave” option)
Average spectrum (AVR) mode – Multi-spectrum in “REPORT” mode
Statistical Analysis
It displays up to 3 percentile levels, between L1 and L99
Probability distribution and percentile level calculation from L1 to L99
• Parameter: LFp, Leq, Lpk A, C or Z -weighted (only C or Z for Lpk)
• Sampling frequency: 8 samples/second
Classification: Classes of 0.5 dB
Combined Data
logging
Parallel profiles, reports, events acquisition
Record of measuring reports with programmable intervals from 1 s to 1 hour with a customizable set of 5 parameters, complete
statistical analysis and frequency spectra.
Analysis of events
• Calculation of 5 freely-programmable event parameters
• Average spectrum calculation by octave and third octave bands
• Calculation of statistical levels from L1 to L99
• Event identification trigger with programmable threshold and duration filter
• External and manual trigger
Reverberation Time
(option HD2010.O4)
Reverberation time measurement using sound source interruption or impulse response integration
Reverberation time calculation in 1/3 octave requires option HD2010.O1 “Third Octave”.
Profile Data Logging 1 profile with sampling 1
/8 s and 3 profiles with 2 samples/second, 5 parameters profiles in “Report” mode with minimum sampling interval 1s.
Spectrum Data
Logging
Programmable sampling from 1 second to 1 hour (AVR mode). Multi-spectrum data logging in “Report” mode with minimum
sampling interval 1s.
Display
Graphic backlit LCD display 128 x 64
• 3 parameters in numeric format
• Profile LAFp with 8 samples/second
• Octave band spectrum from 32 Hz to 8 kHz
• Third octave band spectrum from 25 Hz to 12.5 kHz (option “Third Octave” )
• Graph of sound level probability distribution
• Graph of percentile levels from L1
 to L99
Memory Internal, equal to 8 MB (4 profiles for 23 hours or over 23 recording days of 3 parameters + spectra per minute)
External, via the HD2010MC memory card interface, using MMC or SD cards up to 2 GB
Input/Output
• RS232 serial and USB interfaces
• AC output (LINE)
• DC output
PC Programs
Noise Studio (supplied with the instrument): PC interface for data download, set up and instrument management.
Licensed software modules to be enabled by hardware key.
• NS1“Workers protection” module. Analysis of noise in the workplace in accordance with ISO 9612/2011 and UNI 9432/2011.
• NS2A“Acoustic pollution” module. Analysis of environmental noise. Analysis of the noise climate and assessment of noise
from road, rail and airport according to the law. Some of the functions need option “Third octaves”.
• NS3“Acoustic Insulation” module. Evaluation of airborne sound insulation, impact noise and sound absorption; buildings
insulation classification (UNI 11367). Some of the calculation require option “Third octaves” and option “Reverberation
time” installed in the sound level meter. Calculation according to ISO 16283, ISO 717 and ISO 354.
• NS4 “Monitor” module. Acquisition in real time on PC. Synchronized audio recording. Remote monitoring and data capture.
Connection via Modem.
• NS5”Environmental Noise” module: environmental noise analysis. Noise sources identification with threshold conditions.
Tonality and impulsiveness evaluation. Some of the functions require „Third octave“ option.
Operating Conditions Working temperature -10…50 °C, 25…90% RH (not condensing), 65…108 kPa. Protection degree: IP64
Power Supply 4.8 V / 2.1 A NiMH rechargeable battery or external 5÷24 Vdc / 500 mA
Dimensions and
weight
445 x 100 x 50 mm equipped with preamplifier, 740 g (with batteries)

Delta OHM HD2010UC/A.Kit1 - Class 2 Integrating Sound Level Meter And Analyzer için önerilen ürünler:


Delta OHM HD5014bNI…TCV - Web Data Logger
Delta OHM LP471SILICONPYRA - Pyranometer with Silicon Photodiode
Delta OHM HDBV-1000 - IEPE Triaxial High Sensitivity Accelerometer 10V/g
Delta OHM HD2050.20 - Power Amplifier/Noise Generator
Delta OHM HD22.3 - - Electrode Holder
Delta OHM HD788TR1-I - Opto Insulated Temperature Transmitter
Delta OHM HD32.35 - Housing with Acquisition System for Weather Stations
Delta OHM HD35ED4r… - Wireless Data Logger System
Delta OHM LPUVA01 - Irradiance Probe
Delta OHM HD51.3D147 - High Performance Two Axes Ultrasonic Anemometer
Delta OHM DO9786T-R1 - Panel Mounting Conductivity Transmitter
Delta OHM HDP356A02 - IEPE Triaxial Accelerometer – 10 mV/g
KWD ZAKU-N A 63000 - Coupling
Festo LFR-1/2-D-7-MIDI - - 162706
Festo ADVU-32-30-A-P-A - - 156621
Industrie technik DB-I4D/02/002 - Digital controllers, 4 stages with relay
Gefran TDP-1001 - INDUSTRIAL
Berarma 01 PHPK 3-80 Pump -
American Industrial AB-1210-FP - Parts
Festo SIEF-Q40S-NA-S-2L - - 538342
Gefran GPC- 2PH 500A - POWER CONTROLLERS
Festo DSBC-50-400-PPVA-N3 - - 1366958
ETP ETP-MINI R-14 - Hub-Shaft connections
Gefran TKDA-B06U - INDUSTRIAL