Delta OHM HD35ED7P/3 TC - Wireless Data Logger System

Delta OHM

Ürün Kodu: HD35ED7P/3 TC
Marka: Delta OHM

Teklif Al! info@fabrikaparca.com

Delta OHM HD35ED7P/3 TC - Wireless Data Logger System için Açıklama:

Versions HD35AP: USB output only
HD35APS: USB and RS485 MODBUS-RTU outputs
HD35APW: USB output, Wi-Fi and Ethernet interface
HD35APG:USB output and GSM/GPRSmodule
HD35AP3G:USB output and 3G/GSM/GPRSmodule
Power supply Internal 3.7 V lithium-ion rechargeable battery,
capacity 2250 mA/h, JST 3-pole connector
Optional 6 Vdc external power adapter (SWD06)
Powered directly from the PC USB port (*)
Power consumption ≈30 mA (E, U) / ≈38 mA (J) without Ethernet/Wi-Fi and
with typical GSM/3G activity (**)
≈180 mA with Ethernet, ≈150 mA with Wi-Fi
Battery autonomy
(typical)
≈3 days (E, U) / > 2 days (J) if not connected to the
local network and with typical GSM/3G activity (**)
≈12 hours with Ethernet, ≈14 hours with Wi-Fi
Transmitting frequency 868 MHz, 902-928 MHz or 915.9-929.7 MHz (not for
HD35APG) depending on the model
Antenna Fixed whip external RF antenna
Whip external GSM/3G antenna with cable (HD35APG
and HD35AP3G only)
Transmitting range See table 2
Serial outputs USB with Mini-USB type connector (cable CP31)
RS485 with MODBUS-RTU protocol (HD35APS only)
Ethernet connection Only in HD35APW model. Permits (if the Internet
connection is available) sending alarm e-mail and
the recorded data via e-mail, to an FTP address or to
an HTTP server (Cloud). Allows the MODBUS TCP/
IP protocol.
Wi‑Fi connection Only in HD35APW model. Permits (if the Internet
connection is available) sending alarm e-mail and
the recorded data via e-mail, to an FTP address or to
an HTTP server (Cloud). Allows the MODBUS TCP/
IP protocol.
GSM/GPRS connection Only in HD35APG and HD35AP3G models. For
sending alarm e-mail or SMS and data via e-mail, to
an FTP address or to an HTTP server (Cloud). Allows
the GPRS TCP/IP protocol.
3G connection Only in HD35AP3G model. For sending alarm e-mail
or SMS and data via e-mail, to an FTP address or
to an HTTP server (Cloud). Allows the 3G TCP/IP
protocol.
Internal memory The number of samples that can be stored depends
on the type of data loggers connected. The capacity
is 226,700 samples if all the data loggers record 7
quantities.
LED indicators Presence of external power supply, battery charge
level, RF communication status.
Working temperature and
humidity range
-10…+60 °C / 0…85%RH not condensing
Housing Plastic material
Dimensions 135 x 86 x 33 mm (excluding antenna)
Weight 200 g approx. (including battery)
Installation Wall mount support (supplied) for removable
installation or flanges (optional) for fixed installation

Delta OHM HD35ED7P/3 TC - Wireless Data Logger System için önerilen ürünler:


Delta OHM CP2003.30 - 3-Axis Ultrasonic Anemometer
Delta OHM TP87… - Immersion Temperature Probe
Delta OHM HD48…TFP - Temperature Transmitters for Solar Panel
Delta OHM HD2107.1 - Centesimal Thermometer Pt100
Delta OHM HD2256.2 - Bench Top pHmeter-Conductivity
Delta OHM LPPHOT03… Series - Photometric Probes for Illuminance
Delta OHM LR351NB - LR35 Series – IoT Data Loggers
Delta OHM HD2070.K1 - 3-Channel Vibration Analyzer
Delta OHM HD978TR4 - Converter Signal Amplifier – 0…10 Vdc – DIN Rail
Delta OHM HD5014bNTC - Particulate Matter Web Data Logger
Delta OHM LPPYRA03AV - Spectrally Flat Class C Pyranometers
Delta OHM HD988TR1 - Configurable Temperature Transmitter
Festo JMFH-5-1/2-S - - 35548
Festo MXAD-A16 - - 534402
Festo QSML-M5-2 - - 133031
Turbo TF085(N-V-T)P - Header Tank with Threaded Stubs
Hansford HS100S - Water Proof For Cable
American Industrial AB-702-FP - Parts
Festo LFR-1/2-D-MAXI - - 186489
Festo DWC-50-150-Y-G - - 572345
Tractel 260919 - Dynafor Industrial 12.5T
Festo CRQS-M5-6 - - 162861
Festo VUVB-L-M42-AD-Q8-1C1 - - 537473
Bollfilter 2614171 - Sound Absorber