Marka | Gefran |
---|---|
Ürün | Melt High Temperature |
Ürün Kodu | ME PLc-B17U |
Artikel | - |
Ülke | United States (US) |
Durumu | Yeni / Kullanılmamış |
Accuracy (1) H <±0.25%FSO (100...2000 bar) M <±0.5%FSO (17...2000 bar) Resolution 16 bit Measurement range 0..17 to 0..2000bar 0..250 to 0..30000psi Maximum overpressure (without degrading performances) 2 x FS 1.5 x FS above 1000bar/15000psi Measurement principle Extensimetric Power supply 13...30Vdc Maximum current absorption 23mA (40mA with relay optional) Output signal Full Scale FSO 20mA Zero balance (tollerance ± 0.25% FSO) 4mA Response time (10...90% FSO) 8ms Output noise (RMS 10-400Hz) < 0.025% FSO Calibration signal 80% FSO Power supply polarity reverse protection YES Compensed temperature range housing 0...+85°C Operating temperature range housing -30...+85°C Storage temperature range housing -40...+125°C Thermal drift in compesated range: Zero / Calibration / Sensibility < 0.02% FSO/°C Diaphragm maximum temperature 400°C / 750°F Zero drift due to change in process temperature (zero) < 0.02 bar/°C Standard material in contact with process medium Diaphragm: • 15-5PH with GTP+ coating • 17-7 PH corrugated diaphragm with GTP+ coating for ranges <100bar (1500psi) Stem: • 17-4 PH Thermocouple (model ME2) STD : type “J” (isolated junction) Protection degree (with 6-pole female connector) IP65
İmtek Mühendislik Ltd .Şti. Yurtiçi ve Yurtdışında ihtiyaç duyulan teknolojik malzemeleri elektronik,hidrolik, pnömatik sistem yedek parçalarını en hızlı şekilde tedarik etmek amacıyla 2001 yılında Adana'da kurulmuştur.
Türkiye' nin Her Yerinden44448 19Telif Hakkı © İmtek Mühendislik Ltd. Şti. Tüm hakkı saklıdır.