Gefran WN-B07C - Melt High Temperature
Gefran
Ürün Kodu: WN-B07C
Marka: Gefran
Teklif Al! info@fabrikaparca.com
Gefran WN-B07C - Melt High Temperature için Açıklama:
Accuracy (1)
Resolution
Measurement range
Maximum overpressure
(without degrading performances)
Measurement principle
Power supply
Maximum current absorption
Insulation resistance (at 50Vdc)
Output signal Full Scale (FSO)
Zero balance
(tollerance ± 0.25% FSO)
Zero signals adjustment
(tollerance ± 0.25% FSO)
Span adjustment within ± 5% FSO
Maximum allowed load
Response time (10...90% FSO)
Output noise (RMS 10-400Hz)
Calibration signal
Output short circuit ingress and reverse
polarity protection
Compensed temperature range
Operating temperature range
Storage temperature range
Thermal drift in compesated range:
Zero / Calibration / Sensibility
Diaphragm maximum temperature
Zero drift due to change in process
temperature (zero)
Zero drift temperature for Autocompensated version (SP) within the
temperature range 20°C-315°C inclusive
the drift temperature of the housing
Standard Material in contact
with process medium
Thermocouple (model WN2)
Protection degree
(with 6-pole female connector)
H <±0.25%FSO (100...1000 bar)
M <±0.5%FSO (35...1000 bar)
Infinite
0..35 to 0..1000bar
0..500 to 0..15000psi
2 x FS
1.5 x FS above 500bar/7500psi
Extensimetric
15...30Vdc N, C
10...30Vdc B, M
-15....+15Vdc H, L
25mA
>1000 MOhm
5Vdc (M, H) - 10Vdc (N, L)
5,1Vdc (B) - 10,1Vdc (C)
0Vdc (M, N, H, L)
0.1Vdc (B, C)
“Autozero” function
See Manual
1mA
~ 1ms
< 0.025% FSO
80% FSO
YES
0...+85°C
-30...+105°C
-40...+125°C
< 0.02% FSO/°C
315°C/600°F
< 0.04 bar/°C
< 0.005 bar/°C 100 ≤ p < 500 bar
0.0022 %FS/°C p ≥ 500 bar
Diaphragm: • 17-7PH corrugated
diaphragm with GTP+
Stem • 17-4 PH
STD: type “J” (isolated junction)
IP65