Fabrikaparça

Honsberg LABO-HR2VE-I / U / F / C - Flow Transmitter

Honsberg

Ürün Kodu: LABO-HR2VE-I / U / F / C
Marka: Honsberg

Teklif Al! info@fabrikaparca.com

Honsberg LABO-HR2VE-I / U / F / C - Flow Transmitter için Açıklama:

Sensor analog Hall sensors
Nominal width DN 32 / 40 / 50
Process
connection
female thread G 1
1
/4..G 2
(further process connections available on
request)
Metering range 10..160 l/min
For details see
table "Ranges" Pressure loss ~ 4..7 bar at Qmax
Qmax. up to 160 l/min
Tolerance ±10 % of full scale value at constant
viscosity
Viscositystability
mean deviation ±7 %, max. 18 %
(30-330 mm²/s) of full scale value
Pressure
resistance
PS 200 bar
Medium
temperature
-20..+85 °C, optionally -20..+120 °C
Ambient
temperature
-20..+70 °C
Media oil
Wiring see section "Wiring"
Materials
medium-contact
Brass construction:
CW614N nickelled,
CW614N,
1.4305, 1.4310,
hard ferrite
Stainless steel
construction: 1.4571,
1.4310,
hard ferrite
Non-mediumcontact materials
CW614N nickelled
Power supply 18..30 V DC
Power
consumption
< 1 W
Outputs LABO-....I:
Current output 4..20 mA
(alternatively 0..20 mA)
Max. load 500 Ohm
LABO-....U:
Voltage output 0..10 V
(alternatively 2..10 V)
 Load min. 1 kOhm
LABO-....F:
Frequency output
Transistor output "Push-Pull"
(resistant to short circuits, and reversed
polarity protected) lout = 100 mA max.
Selectable frequency, max. 2 kHz
LABO-....C:
Transistor output "Push-Pull"
lout = 100 mA max.
Pulse width 50 ms
Pulse/Value is to be specified when
ordering
Electrical
connection
for round plug connector M12x1, 4-pole
Display yellow LED
(On = Normal / Off = Alarm /
rapid flashing = Programming)
Ingress protection IP 67
Weight see table "Dimensions and weights"
Conformity CE
Installation
location
Standard: horizontal inwards flow; other
installation positions are possible; the
installation position affects the metering and
switching range.

Honsberg LABO-HR2VE-I / U / F / C - Flow Transmitter için önerilen ürünler:


Honsberg OMNI-RT-020AK002. - Flow Transmitter / Switch
Honsberg HV - Flow Indicator
Honsberg BL-008GK - Flow Indicator
Honsberg UM3K-010GM - Flow Switch
Honsberg 018DK045 - Thermal flow sensor OMNIPLUS-F
Honsberg FQ-025GR - Flow Indicator
Honsberg GK-025GTW0250PM - Flow Meter
Honsberg VHS-025...0140 - Flow Transmitter / Screw Volumeter
Honsberg UR3K-040GK - Flow Switch
Honsberg H.O-010GM - Flow Indicator
Honsberg UR3K-020GM - Flow Switch
Honsberg VD-020FK... - Flow Switch
Winsmith U2005HG56 - RD Speed Reducer
Festo VUVG-S14-T32C-MZT-G18-1T1L - - 573467
Festo DNC-50-60-PPV-A - - 1922631
Industrie technik DAK230 - Damper actuators without spring return, 2 Nm
Festo MHP2-PR8-3 - - 197445
Festo MA-40-1-G1/8-MPA - - 192732
Festo DMM-32-50-P-A - - 158552
Unimec RS 86 - Bevel Gearbox
Armatury L32.8 - Butterfly Valve
Industrie technik VFTRB225-8 - VFTRB2/VFTRB3 - 2- and 3-way control valves
Festo VMPAL-KMSK-V-SD25-IP67-5 - - 560411
Gefran TU-K2C - FORCE